DicoFlow LIMS · Laboratory

Every sample, from first draw to a signed, QC-gated report

DicoFlow LIMS plans tubes in order of draw, routes work to the right bench, holds results when the latest QC run failed, and locks every finalized report with a digital signature — on your own server.

The lab workflow

Nine steps, one record per sample

Billing creates the lab order, the specimens and the work assignments. Each step then hands over to the next, with a quality loop running alongside.

  1. STEP 01

    Register & bill

    One screen raises the bill. The lab order, specimens and work assignments are created from it automatically.

  2. STEP 02

    Plan tubes & print labels

    Tests are grouped into tubes in CLSI GP41 order of draw, and 50 × 25 mm Code128 labels print on any thermal printer.

  3. STEP 03

    Collect

    The phlebotomy board, home-collection visits and timed multi-draw protocols, with due and overdue alerts.

  4. STEP 04

    Receive & accession

    Condition and temperature are recorded at receipt. A rejected sample carries a reason code and raises a redraw.

  5. STEP 05

    Route to bench

    Work flows from test to department to role worklist. Incubations run on their own countdown lane.

  6. STEP 06

    Analyze

    Analyzer or manual entry, with the same checks either way: flags, delta check, critical alerts and reflex tests.

  7. STEP 07

    Verify

    Auto-verification rules for analyzer results, then technical and medical review — behind the QC release gate.

  8. STEP 08

    Report & e-sign

    Technician, supervisor and pathologist sign off in turn. The final report is cryptographically signed and locked.

  9. STEP 09

    Dispatch

    Print, email, WhatsApp, SMS or a secure link — with an automatic “report ready” message to the patient.

The quality loop runs alongside every step

QC, external quality assessment and turnaround are recorded as the work happens, not rebuilt at audit time.

Westgard + Levey-JenningsEQAS · CAPA · NABL registersTAT by stage

Pre-analytical

The right tubes, labelled, before the needle goes in

Tests are grouped into tubes, with volume split where needed, and sorted by CLSI GP41 order of draw. Labels print at 50 × 25 mm in Code128 from the browser, to any thermal printer.

  • Accession numbers carry your lab code and the date: CODE-YYMMDD-0001.
  • The phlebotomy board runs In Queue → In Working → Completed. “Collect” stays locked until every tube is barcoded.
  • Batch handover records transport temperature and condition; receipt records condition and temperature again.
  • A sample tracking board shows every tube’s lifecycle on a timeline.

Tube plan

Patient A · 34 Y / F · LAB-261005-0412

CLSI GP41 order of draw

Draw order →

  1. 01Light blue
  2. 02Gold
  3. 03Lavender
  4. 04Grey
  • Sodium citrate

    PT / INR

    Barcoded
  • Serum separator (SST)

    LFT · KFT · Lipid profile — 3 tests, one tube

    Barcoded
  • EDTA

    CBC · HbA1c — 2 tests, one tube

    Barcoded
  • Fluoride oxalate

    Glucose - Fasting

    Print label
Collect

1 tube still to barcode — Collect unlocks at 4/4.

PATIENT A34Y / F
UHID 000418LAB-261005-0412

LAB2610050412

Serum · SSTLFT, KFT, LIPID

50 × 25 mm · Code128 · 203 dpi thermal

Timed draws

Multi-draw protocols for GTT, GCT and diurnal cortisol, with due and overdue alerts.

GTT · Patient D3 draws

  • 0 min08:00Collected
  • 60 min09:00Collected
  • 120 min10:00Overdue 6m

Home collection

Visits booked by slot and tracked from Scheduled through En route to Completed.

Home visit · Rohan G.07:00–08:00

  1. Scheduled
  2. En route
  3. In progress
  4. Completed

Reject, then redraw

Nine reason codes. A rejected sample raises a redraw automatically, without a second bill.

Reject · LAB-261005-03989 codes

HaemolysedClottedInsufficientWrong tubeUnlabelledExpiredLeakingWrong patientOther

Redraw raised · no re-billing

Chain of custody

An append-only trail per tube, with transport temperature and aliquot lineage.

Tube S-0412 · SSTappend-only

  1. Collected08:12
  2. Handover · 2–8 °C · intact08:40
  3. Received & accessioned08:55
A1 · BiochemA2 · Sendout

Bench & results

Every result passes the same checks — analyzer or manual

Work routes automatically from test to department to role worklist. Whether a value arrives from an analyzer or is typed at the bench, it is checked the same way before anyone can verify it.

  • Reference ranges by sex, age and condition — and the report shows which range applied.
  • Delta check against the previous result; absurd values held at hard limits (CLSI AUTO10-style).
  • Critical value desk with live alerts, escalation counters and mandatory read-back. Sign-off stays blocked until every critical is acknowledged.
  • Rule-based reflex tests with billing rules, and an incubation countdown lane for cultures, AFB, ESR and ELISA.
  • Multi-parameter panels (urine, stool, semen, CBC), calculated tests from a formula engine, and re-runs with full history.

Result entry · Biochemistry

Patient C · 29 Y / F · LAB-261005-0421

Analyzer result
  • Sodium

    136 – 145

    138mmol/L

    Normal
  • Potassium

    3.5 – 5.1

    6.9mmol/L

    Critical
  • Creatinine

    0.5 – 1.1 · Female, 18 y+

    1.9mg/dL

    HΔ 0.8 → 1.9
  • TSH

    0.1 – 2.5 · Pregnancy, 1st trimester

    4.6µIU/mL

    HReflex · Free T4
  • Uric acid

    2.6 – 6.0 · Female

    72mg/dL

    Absurd value · held

Critical value desk

1 open

Potassium6.9 mmol/L

Patient C · escalation ×2 · open 14 min

Read-back recorded required
Sign off — blocked

Until every critical is acknowledged

Incubation lane

4 running
  • Urine culture18h 20m left

  • AFB culture39d 04h left

  • ESR38m left

  • ELISA52m left

Quality control

QC that blocks release, not just reports it

Westgard multirule is evaluated on the server for every QC run. When the latest run on an instrument or department fails, its results stay held until QC passes.

Levey-Jennings · Glucose · QC level 2

30-day view · Westgard multirule evaluated on the server

Latest run: 1-3s reject
+3SD+2SD+1SDMean-1SD-2SD-3SD2₂s reject1₃s reject
In control Warning (beyond 2 SD) Rule violation

Westgard multirule

Six rules, applied to every QC run.

  • 1-2sOne control beyond ±2 SDWarning
  • 1-3sOne control beyond ±3 SDReject
  • 2-2sTwo in a row beyond the same 2 SD limitReject
  • R-4sTwo controls more than 4 SD apartReject
  • 4-1sFour in a row beyond the same 1 SD limitReject
  • 10xTen in a row on one side of the meanReject

QC release gate

No result is released unless the latest QC run on that instrument or department passed. The check runs three times — at both verification levels and again at finalize.

Latest QC run · Chemistry analyzer · 09:40Failed
  1. Technical verifyHeld
  2. Medical verifyHeld
  3. FinalizeHeld

Auto-verification, rule by rule

Rules are set per test and apply to analyzer results. A result is auto-verified only when every condition holds; anything else goes to technical, then medical review.

  • Result within range
  • No delta-check flag
  • Latest QC passed
  • Received from the instrument
  • No critical value
  • Auto-verified

Reports & e-signature

Signed in sequence, then locked

Technician, supervisor and pathologist sign off in turn, and the report reads “NOT VALID” until the last signature. On finalize it is locked with a SHA-256 hash and an Ed25519 signature.

Sign-off chain

RPT-261005-2E19

Finalized
  1. Technician10:12

    Results entered · technical review

  2. Supervisor10:31

    Medical verification

  3. Pathologist10:41

    E-signed

Locked on finalize

SHA-256
9f2c7e…a1b4d041
Ed25519
signature valid
ULR
NABL2600000304F

Versions

  • RPT-261005-2E19Original
  • RPT-261005-2E19-A1Amendment · same ULR

Each report carries a NABL ULR number. An amendment creates a new version (-A1, -A2…) under the same parent ULR, so the history stays readable. Microbiology, histopathology and cytology use templated reports.

34 report layouts
Matched to each test automatically — CBC, culture & sensitivity, histopathology, Bethesda cytology, coagulation, dynamic endocrine, health check-up and more.
One shared report editor
Results grid with rich text, images, templates and macros, a live A4 preview, autosave and an edit lock.
Two print themes
Traditional Indian letterhead or Modern. Upload your logo and letterhead, or print without a header on pre-printed stationery.
Cumulative trend report
Previous results side by side, with trend arrows and sparklines for each parameter.
Partial & preliminary release
Release part of a report with a recorded reason, backed by a 72-hour escalation.
Report booklets
One combined PDF for the patient, with a cover page and an index.

Analyzer interfacing

Results arrive from the analyzer, not the keyboard

DicoFlow LIMS supports ASTM E1394, HL7 v2.x over MLLP and CSV file drop, across five connection modes. On ASTM and HL7 links the conversation runs both ways: host query in, worklist down, results back.

  • Every message is saved to a journal before it is processed.
  • Unit mismatches on incoming results are detected.
  • Named drivers built from vendor interface specifications: HORIBA Yumizen H550E (haematology, bidirectional), bioMérieux mini VIDAS and VIDAS KUBE, ACON Mission U120 (urine).
  • Analyzer results go through the same flags, delta and critical checks as manual entry.

Three analyzer interfaces are included in Year 1. More can be added later as add-ons — ask for a quote with your analyzer list.

Named drivers

  • HORIBA Yumizen H550E

    HaematologyBidirectional

  • bioMérieux mini VIDAS

    ImmunoassayResults

  • bioMérieux VIDAS KUBE

    ImmunoassayResults

  • ACON Mission U120

    UrineResults

5 connection modes
TCP serverTCP clientRS-232 serialFolder watchFTP / FTPS polling
Protocols

ASTM E1394

over E1381

HL7 v2.x

over MLLP

CSV

file drop

Host query · worklist download

DicoFlow LIMS · message journal

saved before processing
  • ASTMR|1|^^^HGB|11.2|g/dLparsed
  • HL7ORU^R01 · 14 resultsparsed
  • HL7QRY^Q02 → ORM^O01 worklistsent
  • FILEresults.csv · GLU unit mismatchflagged

Quality & NABL

Accreditation evidence, kept as you work

DicoFlow LIMS is designed to support NABL accreditation evidence. The ISO 15189:2022 clause register comes pre-loaded with 36 clauses for gap analysis, and the quality registers sit next to the work they describe.

  • Quality registers and dashboards, including a NABL compliance-score view.
  • Westgard multirule QC with 30-day Levey-Jennings charts, plus inventory and calibration-due views.
  • NABL ULR numbers on reports; amendments keep the parent ULR.
  • A tamper-evident, hash-chained audit trail and an append-only custody trail per tube.
  • Lab results, text and interpretations encrypted at rest with AES-256-GCM.

ISO 15189:2022 clause register

Gap analysis · 36 clauses pre-loaded

Self-assessment

Met 23 Partial 9 Gap 4

  • 5.6Risk managementPartial
  • 6.2PersonnelMet
  • 6.5Equipment calibration and metrological traceabilityMet
  • 7.3.7.2Internal quality controlMet
  • 7.3.7.3External quality assessmentPartial
  • 8.3Control of management system documentsMet
  • 8.7Nonconformities and corrective actionsGap

Quality registers

  • EQAS
  • CAPA
  • Internal audit
  • Risk register / FMEA
  • Document control & SOPs
  • Quality indicators
  • Competency & training
  • Inventory & calibration due

Dispatch & turnaround

Delivered, confirmed and on the clock

The dispatch counter refuses unsigned reports and marks a delivery as sent only when the provider confirms it. Turnaround is tracked across six stages, each with an owner.

Dispatch counter

Proof-of-dispatch log for every report

  • Patient A

    RPT-261005-2E19

    Delivered
  • Rohan G.

    RPT-261005-2F07

    Awaiting provider
  • Patient C

    RPT-261005-2F11

    Handed over
  • Patient D

    RPT-261005-2F15

    Refused · unsigned
Hello Patient A, your lab report is ready. — Your Diagnostic Centre10:42 ✓✓

Automatic “report ready”: WhatsApp firstSMS fallback

Lab TAT by stage

Median today vs target · each stage has an owner

  • Collection · Phlebotomist

    6m/15mQuick
  • Receiving · Lab technician

    11m/15mNormal
  • Analysis · Lab technician

    52m/60mLate
  • Verification · Supervisor

    19m/15mBreached
  • Reporting · Pathologist

    9m/30mQuick
  • Dispatch · Reception

    3m/10mQuick
Quick Normal Late BreachedBreach alerts on

Secure share link

Valid for 72 hours, with an optional password. The recipient needs no login.

Role boards

Phlebotomist, technician, supervisor and pathologist boards with live TAT badges, on-time % and median times.

Your own providers

Connects to your WhatsApp, SMS and email provider accounts. Targets and breach alerts are configurable.

Report layouts
34

Auto-matched per test

Disease panels
263

ICD-10-tagged, 17 categories

Starter-catalogue tests
270

12 departments, one click

ISO 15189:2022 clauses
36

Pre-loaded for gap analysis

FAQ

Questions labs ask us

Short answers on analyzers, NABL, QC, criticals, set-up and licensing.

See your own test menu on DicoFlow LIMS

Book a guided demo on your own test menu, analyzers and report layouts. We will show the screens your phlebotomists, technicians and pathologists use.